Gossen SI 232-II Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měření, testování a kontrola Gossen SI 232-II. Gossen SI 232-II User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - 3-348-636-02

Operating Instructions3-348-636-026/5.04SI 232-II, BD 232 Interface Adapterwith METRAwin 10 / METRA Softwarefor Measuring and Recording Systems with M

Strany 2 - 2 GOSSEN METRAWATT GMBH

10 GOSSEN METRAWATT GMBH5.2 DisplayFigure 4.3 Memory Adapter LCD1 Digital DisplayThe current menu item appears at the 7 segment liquid crystal display

Strany 3 - GOSSEN METRAWATT GMBH 3

GOSSEN METRAWATT GMBH 115.3 Switching the Memory Adapter ON and OFFBriefly press the right-hand ON/OFF key in order to switch the memory adapter ON.Th

Strany 4 - 3.1 General Information

12 GOSSEN METRAWATT GMBH6 Operating Instructions at a GlanceThe memory adapter can be operated with the keypad on the device, or more conveniently wit

Strany 5 - GOSSEN METRAWATT GMBH 5

GOSSEN METRAWATT GMBH 136.3 Shortcuts at the Multimeter • Select Normal Operation– Switch the device off, and then back on.– Or, if the device is in t

Strany 6 - 6 GOSSEN METRAWATT GMBH

14 GOSSEN METRAWATT GMBH6.4 Menus Overview Test4mm:sshh:mmddmm:sshh:mmddmm:sshh:mmddmm:ssYESno38400noModEMnnnnnHirAtE HYSt triG CYCLE tIME Addr bd-ouS

Strany 7 - 4.1 Connecting the Adapter

GOSSEN METRAWATT GMBH 157 Menu Item Descriptions7.1 Set Sampling Rate – rAtEKey Sequence: SEt rAtE m:ss.hh Settings: m = minutes, ss = seconds,

Strany 8 - 8 GOSSEN METRAWATT GMBH

16 GOSSEN METRAWATT GMBH7.3 Trigger Settings – triGThe trigger setting determines which multimeter measurement values will be stored to the adapter. B

Strany 9 - 21.978 mA

GOSSEN METRAWATT GMBH 17• Disabling the TriggerKey Sequence: SEt ... ... trIG oFF tiME oFF Settings: triG = oFF, the trigger is disabled•

Strany 10 - 5.2 Display

18 GOSSEN METRAWATT GMBH7.4 Recording: Duration and Type – durA, CYCLE• Recording without Time Limits – durAKey Sequence: SEt ... ... durA on

Strany 11 - 5.4 Replacing the Batteries

GOSSEN METRAWATT GMBH 197.7 Set Transmission Speed – bAud-ou, bAud-in• Set Transmission Speed to the PC – bAud-ouKey Sequence: SEt ... ... bAud-

Strany 12 - key as well

2 GOSSEN METRAWATT GMBHContents Page1 Introduction ...

Strany 13 - • Select Normal Operation

20 GOSSEN METRAWATT GMBHStart manual data recording:Shortcut: Press and hold the yellow ESC key and press the key once for each desired measurement.

Strany 14 - 6.4 Menus Overview

GOSSEN METRAWATT GMBH 21• View Individual, Recorded Measurement ValuesKey Sequence: rECAll bbbb StAt SEE (bEGin) ... nnnnn1 ... nnnnnm ... (E

Strany 15 - 7 Menu Item Descriptions

22 GOSSEN METRAWATT GMBH7.10 Reading Out Data from the Adapter at the PC / Parameter Configurations – PCKey Sequence: PC PC-nnSettings: nn = selected

Strany 16 - 7.3 Trigger Settings – triG

GOSSEN METRAWATT GMBH 23 Figure 4.5 LCD Test• Internal Memory TestKey Sequence: InFO tiME tESt diSP rAM no YES buSYSettings: no = no memory

Strany 17 - • Disabling the Trigger

24 GOSSEN METRAWATT GMBH8 METRAwin 108.1 Installing METRAwin 10WINDOWS version 3.1 or higher is required for installation.METRAwin 10 is installed aut

Strany 18 - ModEM no YES

GOSSEN METRAWATT GMBH 259 Memory Adapter Technical DataSupported Measuring InstrumentsMETRAHit 12S ... 16S, 16I/T, 18S, 14A, 22S/M ... 29SOperating El

Strany 19 - StorE ...)

26 GOSSEN METRAWATT GMBHPower Supply:2 ea. 1.5 V mignon cellsDry cell per IEC R6 type 3006: 1100 mAhAlkaline-manganese per IEC LR6 type 4006: 2300 mAh

Strany 20 - • Interrupt Data Recording

GOSSEN METRAWATT GMBH 2710 Repair and Replacement Parts ServiceDKD Calibration Lab and Rental Instrument ServiceWhen you need service, please contact:

Strany 21 - Select recording time

GOSSEN METRAWATT GMBHThomas-Mann-Str. 16-2090471 Nuremberg, GermanyPhone +49-(0)-911-8602-0Fax +49-(0)-911-8602-669E-Mail: [email protected]

Strany 22

GOSSEN METRAWATT GMBH 31 IntroductionInterface AdapterWhereas interface adapter BD232 allows for online transmission of measured values from multimete

Strany 23 - • Internal Memory Test

4 GOSSEN METRAWATT GMBH3 Multimeter, Adapter and METRAwin 10 Operating Modes3.1 General Information• The address for the adapter and its corresponding

Strany 24 - 8.3 Starting METRAwin 10

GOSSEN METRAWATT GMBH 53.4 Configuring Multimeter Parameters– for all METRAHit 2x with SI232-II or BD232 3.5 Receiving Live Measurement Data from the

Strany 25 - GOSSEN METRAWATT GMBH 25

6 GOSSEN METRAWATT GMBH3.6 Saving Measurement Data to the SI232/-II Memory AdapterThe memory adapter can be used with all multimeter versions. Excepti

Strany 26 - Mechanical Design

GOSSEN METRAWATT GMBH 74 Adapter Connection and Initial Start-Up4.1 Connecting the AdapterThe screw connections between the stacked adapters serve exc

Strany 27 - 11 Product Support

8 GOSSEN METRAWATT GMBH➭ After selecting the “File/Measure” menu item, the recorded measurement values are transmitted to the PC and are displayed at

Strany 28

GOSSEN METRAWATT GMBH 95 Operating Elements, Switching the Adapter ON and OFF, Replacing the Batteries5.1 Keypad, InterfaceFigure 4.2 Memory Adapter O

Komentáře k této Příručce

Žádné komentáře